Unox BAKERLUX SHOP.Pro – Contactors are Chattering
On your BAKERLUX SHOP.Pro unit, chattering contactors typically indicate an unstable power…
On your BAKERLUX SHOP.Pro unit, error code WC01 indicates a temperature probe warning within the hood system, suggesting either a dislodged connection or a faulty probe. Verify the probe's connection to the P7 socket on the hood power board. If connections are secure, measure the probe's impedance to confirm its integrity.
Q: What does the WC01 error code signify on my UNOX BAKERLUX SHOP.Pro oven?
A: The WC01 error code on a UNOX BAKERLUX SHOP.Pro oven indicates a warning related to the hood’s temperature probe, suggesting it may be disconnected or faulty, impacting temperature monitoring.
Q: How can I verify if the temperature probe is working correctly?
A: To verify, first ensure the temperature probe is securely connected to the P7 socket on the hood power board. Then, use a multimeter set to ohms to measure its impedance; it should read approximately 110 ohms at 25 °C (77 °F).
Q: What steps should I take if replacing the temperature probe does not resolve the WC01 error?
A: If replacing the temperature probe does not clear the WC01 error, and its impedance tests correctly, the issue may lie with the hood power board itself. In this scenario, the next step would be to replace the hood power board.
For this error, we recommend calling a certified technician. Do not continue operation or attempt repair yourself.